Availability: | |
---|---|
Fibra Optica Spalatensis, quae fibra optica SCHISMATICUS vel faba SCHISMATICUS nota est, typum est potentiae administrationis optica machinae ad signa optica a Central Officio (CO) distribuenda, ad multa praemissa signatoria loca.PLC Spalatensis Optical munus cruciale in PON retis ludit.Fundatur in Technologia Planar Waveguide, sumptus efficens et spatium praebet solutionem retis salvificae.Fiber opticus PLC SCHISMATICUS signum opticum ab uno vel duobus fibris initus ad plures portus output uniformiter dividit.Esse opus ab 1260nm ad 1650nm.PLC dialecticis adhiberi possunt sub terra, aere, basi et eculeo systemata montis.
PLC dialecticis typice instituuntur ut retiacula PON et FTTH inserviant.1xN et 2xN rationes communes SCHISMATICUS pro applicationibus specificis.Aptissimum eligere debes secundum propositum tuum.
ABS Box PLC Splitter
Potest etiam referri ut ABS Cassette PLC Splitter vel ABS Module Type PLC Splitter.Fibrae inligatae ac fibrae distributiones in eadem lamina huius ABS Box dispositae sunt, quae ad varias institutiones requisita et solutiones cabling magis flexibiles accommodare possunt.Praeterea institui etiam potest in variis capsulis vel clausuris.OMNIBUS SCHISMATICUS, etiam cassette SCHISMATICUS, designatus cum 2.0nm vel 3.0nm fibra output directa designatus est.Hoc genus ABS Box SCHISMATICUS adhiberi solet ad usum tabulae plenitudinis, sicut arca retis et cistae opticae distributio.Valet etiam opus ad splice ac melius fibra tuenda uti.Typical moduli genus SCHISMATICUS cum ABS sarcina archa.
Features
Uniform potentia fissile
modulus cassette pacto consilio
Broadband Operatio Necem
Bonum alveum-ad-alveum uniformitas
Humilis PDL (Polarisation dependens Loss)
Low insertio Loss and high Return Damnum
Certa Environmentally et mechanice stabilitas
Lata Operating Necem: Ab 1260nm ad 1650nm
Lata Operating Temperature: Ab -40°C ad LXXXV°C
Testimonio ROHS
Applications
FTTX (FTTB, FTTH, FTTC) Systems
Cable televisificae (CATV)
Optical signum Distributio
Active Network passivus (PON)
Locus area retiacula (LAN)
Optical signum distributio & Test armorum
Optical Splitters in PON/FTTx Solutio Mathematica
Product ornare ipsum
Certa Environmental stabilitas
Minimum inserere damnum (IL), humilis polarisation dependens damnum (PDL), humilis retro reflexionem et uniformitatem egregiam.
Summus qualitas Chips
Necem non sentit in amissione lucis, quae potest occurrere postulationi transmissionis diversorum aequalitatum.
Module Cassette Design Foedus
Haec ABS PLC SCHISMATICUS utitur ABS plasticae arcae ad scindendum chippis tenendas ut firmiorem & firmiorem tutelam praebeat.
Flexibile installation
Hoc ABS cassette genus SCHISMATICUS valde commune est instituendus in norma 19-inch eculeo unitatis.
Optimus solutio pro passivis Optic Network (PON)
ABS cassette genus SCHISMATICUS adhibetur ad signa optica distribuere vel iungere, quae permittit tabellarius telecomes & ISP signa scindendi ad plures domos, aedificationes et officia.
Materia durabilis Jacket
PVC et LSZH libitum sunt, et utrumque cum bono robore et tenacitate longae vitae.
Qualitas stricte Imperium
Omne productum est stricte prius probatum sit amet.TANGPIN Technologia spondet omne productum ad manus clientium sub signis probationis durissimis esse.
Decern Packaging
Consilium et packaging exquisitum est efficere ut fructus venientes in bonam condicionem ad emptorem pertineat.
Valde sterilis
Omnis materia rudis ante horrea nostra sterilis erit.Proin consequat sit amet ante et venenatis.
Specification
Table 1
1×N PLC Splitter
Morbi laoreet | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 |
Operans Necem (nm) | 1260~1650 | |||||
Fibra Type | G652D/ G657A1/G657A2 vel elit specificatur | |||||
Insertio Damnum (dB) (P/A Gradus) | 3.8/4.0 | 7.1/7.3 | 10.2/10.5 | 13.5/13.7 | 16.5/16.9 | 20.5/21.0 |
Damnum Uniformitas (dB) | 0.4 | 0.6 | 0.8 | 1.2 | 1.5 | 2 |
Redi damnum (dB) (P/A Gradus) | 50/55 | 50/55 | 50/55 | 50/55 | 50/55 | 50/55 |
Polarisation dependens damnum (dB) | 0.2 | 0.2 | 0.2 | 0.25 | 0.3 | 0.35 |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
Necem dependens damnum (dB) | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 |
Temperature Stabilitas | 0.4 | 0.4 | 0.4 | 0.5 | 0.5 | 0.5 |
Temperatus operating (°C) | -40~85 | |||||
Repono Temperature (°C) | -40~85 | |||||
sarcina | Libitum (plastic peram, chartam archa vel plastic lance) |
Table 2
2×N PLC Splitter
Morbi laoreet | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
Operans Necem (nm) | 1260~1650 | |||||
Fibra Type | G652D/ G657A1/ G657A2 vel mos specificatorum | |||||
Damnum insertio (dB) | 4 | 7.6 | 11 | 14.4 | 17.5 | 21 |
Damnum Uniformitas (dB) | 0.6 | 1 | 1.2 | 1.5 | 1.8 | 2.2 |
Redi damnum (dB) (P/A Gradus) | 50/55 | 50/55 | 50/55 | 50/55 | 50/55 | 50/55 |
Polarisation dependens damnum (dB) | 0.2 | 0.2 | 0.3 | 0.3 | 0.4 | 0.4 |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
Necem dependens damnum (dB) | 0.3 | 0.4 | 0.5 | 0.5 | 0.5 | 0.5 |
Temperature Stabilitas(-40~85 °C)(dB) | 0.4 | 0.4 | 0.4 | 0.5 | 0.5 | 0.5 |
Temperatus operating (°C) | -40~85 | |||||
Repono Temperature (°C) | -40~85 | |||||
sarcina | Libitum (plastic peram, chartam archa vel plastic lance) |
Ordo Information
Input Channel Number: 1/ 2
Input Fiber Optical Type: 0.25mm / 0.9mm / 2.0mm / 3.0mm
Output Channel Number: 2 / 4 / 8 / 16/ 32 / 64
Output Fiber Optical Type: 0.25mm/ 0.9mm / 2.0mm / 3.0mm
Connector Type In/E: nullus connector / FC / SC / LC / vel alius generis
Connector Poloniae Type: APC/UPC/PC
Fibra Longitudo: nativus (1.5M defaltam)
TANGPIN's ABS PLC Splitter familia includit 1×2, 1×4, 1×8, 1×16, 1×32, 1X64, 2×2, 2/4, 2×8, 2×16, 2×32, 2x64 PLC dialecticis.
Q&A
Q: Estne hoc ABS Box typus PLC SCHISMATICUS adhiberi potest pro fibra optica clausurae splice?
A: Minime, Si SCHISMATICUS opus in FOSC instituendum (splice fibri optici clausurae), inobstituto PLC SCHISMATICO uti potes.Hoc SCHISMATICUS valde commune est ut in regula constituatur unitas 19 inch eculeo.
Q: Isne SCHISMATICUS tantum usus est ad vexillum 19-inch eculeus mons?
A: Hoc SCHISMATICUS etiam in capsa optica distributionis velit adhiberi potest pro fibris ad punctum (FTTx) instruere, CATV nexus et alia retiacula optica passiva (eg, EPON, GPON, BPON).
Q: Quomodo eligere rectam fibra SCHISMATICUS opticus?
A: Sumptibus & applicationibus considerare.
Exempli gratia, configurationes infra 1×4 scindentes monentur ut FBT SCHISMATICUS uti, dum schemata supra 1×8 scinduntur, pro PLC dialecticis commendantur.Si tantum pro uno necem transmissione vel duali, FBT SCHISMATICUS melius est ut sumptus servandi.Si ad PON divulgationem transmissionis, considerando dilatationem futuram et vigilantiam necessitates, PLC SCHISMATICUS melior est.
Q: Hoc est SCHISMATICUS IMPERVIUS?
A: PLC dialecticis praebemus, IMPERVIUS non est.
TANGPIN Technologia praebet seriem fibrarum opticorum phistarum, praeter ABS cistae PLC schistae, nos etiam offerre tubum minium PLC schismatis, obturaculum-in cassette genus SCHISMATICUS, equuleus PLC phisicus, ventilator PLC SCHISMATICUS, Tray genus PLC SCHISMATICUS; LGX PLC phisicus et nudum fibra PLC scindens.